{"id":"CVE-2026-80145","published":"2026-09-22T16:18:00.570","lastModified":"2026-09-24T19:17:17.333","description":"Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.","cvssScore":9.1,"cvssSeverity":"CRITICAL","cvssVector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","cwes":["CWE-78"],"vendors":[],"products":[],"references":[{"url":"https://revrb.net/2026/09/21/revrb-lantern.html","tags":[]},{"url":"https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/","tags":[]},{"url":"https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/","tags":[]},{"url":"https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/","tags":[]},{"url":"https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/","tags":[]},{"url":"https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password","tags":[]}],"exploitRefs":[],"hasPoc":false,"ai":{"summary":"This vulnerability allows authenticated attackers with services permission to execute arbitrary shell commands as root, leading to complete loss of confidentiality, integrity, and availability on the affected device.","exploitability":"Exploitation is relatively straightforward for attackers with the necessary permissions, as the set cifs password command is vulnerable to command injection.","blast_radius":"If exploited, the vulnerability can impact the entire device and potentially downstream serial-attached devices, leading to significant damage.","remediation":"Upgrade to firmware v9.7.0.2 or later for SLC8000/SLC9000, v9.7.0.1 or later for EMG8500/EMG7500, and ensure all firmware versions of SLB882/SLCx-03/SLCx-02 are patched.","detection":"No reliable host or network indicator is derivable from the published description.","tags":["rce","auth-bypass","command-injection","firmware","critical"],"model":"qwen2.5:7b-instruct","analyzedAt":"2026-09-28T08:50:25.983Z"}}